Rotary Tablet Press – “Accura” Model Act II Single Rotary Tablet Press

With Exchangeable Turret

(WITH CFC AND AWC, FACILITY)

31 STN “D” Tooling / 37 STN “B” Tooling / 45 STN “BB” Tooling

Single Rotary Pill Press

THE Rotary Tablet Press MACHINE IS HAVING FOLLOWING MAJOR SALIENT FEATURES: –

  • SINGLE ROTARY TABLET PRESSES WITH EXCHANGEABLE TURRET.
  • With Motorized pre compression of 10 Tons. (100 KN)
  • With Motorized main compression of 10 Tons. (100 KN)
  • With Motorized dozzer, for precise depth of fill adjustment.
  • With auto weight control (A.W.C)
  • With Industrial PC/HMI, having 15” colour touch Panel
  • With Load cell at pre- compression & main compression
  • With load cell for lower punch tight detection
  • With Auto sampling based on, either time or revolution or Punch no.
  • With auto rejection, of any single tablet, out of prescribed
  • compaction force limit.
  • With Easy Turret Change facility
  • Vibration free and easy to operate at 70RPM
  • Turret Can be changed within a very small time segment.
  • Reduces the product change over time.
  • can have an option for the use of any turret having
  • tooling 31-D or 37- B or 45 BB
  • No more cubical required. All three type of tablet compression
  • available on the same rotary tablet press machine
  • Save cost of Multiple operators
  • Save cost of Multiple Spares
  • Saves cost of Multiple Cubicles
  • Reduce the tablet rejection by AWC
  • Provide accurate weight & tablet quality.
  • Optimize various tab, Parameters like hardness thickness & weight
  • Eliminates maximum human errors.
  • Auto Lubrication on Specific Points & Grease Lubrication on other points.
  • No Hydraulics, No Oil, No Oil Leakage.
  • Rotary tablet press machine with manual over-ride facility Incase of failure of PLC / HMI
“3 IN 1” – “D –B & BB” Tooling operation within one cubical space only. Now, No need for three separate cubicles. (an accura advantage)
Exchangeable Turret (An Accura Advantage)
Turret Change / Exchange Looking to the increasing demand from pharma Industries, for this type of mechanism, Fluidpack’s ACCURA ACT – II single rotary Tableting Machine is manufactured / Crafted with great precision and with easy & specially designed turret device, It can be operated through the soft push button on Touch Screen. Keeping in mind the highest safety for tablet press there are upper & lower limits, on the travel range of the turret lifting rail, which prevents any damage caused by the non- proper operation. Turret is lifted up & down, from the top of it, by connecting it with a cantilevered, lifting linier sliding rail mechanism. Turret, then after, can be pulled out and can be unloaded on specially designed trolley. Another Turret can be immediately replaced by this mechanism on the machine with a very small time segment.
Operation Through Control Panel (By Ipc- Industrial Pc)
  • Having Castor Wheels, for easy movement
  • IPC (Industrial P.C.) With 15” Colour Touch Screen
  • Easy to operate by soft touch
  • Visual indication on safety messages.
  • The Batch data can be recorded automatically & down loaded.
  • The information of product can be recorded & saved under a file name.
  • 3 Way password system
  • With a Screen having various sections, making scanning and impact
  • of data, easily
  • The display and recorded data can be printed also.
  • The after sales, PLC complaints can be carried out by internet, Separate
  • E-Mail connection and can be carried out comfortably in the operation
  • terminal.
  • The data can be stored.
  • Pen drive connectivity
  • 21 CFR Part 11 Compliance
AWC – (Automatic Weight Controller) (an accura advantage)
  • The range of AWC is divided such as control, reject and data store.
  • Graphical appearance of the value of pre & main pressure.
  • Display of figure and graph both for the value of pressure on each individual punch.
  • Indication / Display, of any no. of the selected punch & the respective value of pressure applied on it.
  • Filling depth can be adjusted, if the amount of filled powder is exceeded or shortened beyond preset value.
  • The faulty tablet will be rejected automatically.
  • All data like production, rejection samples taken. Batch time segment etc. is recorded.
  • Discharge chute with three compartments like initial reject, auto reject & sampling gate.
  • The set parameters and the actual parameters can be visualized on the screen, at the same time.
  • Empty punch can set.
Centralized Scada Monitoring System (an accura advantage)
Machine input & output status can be observed & monitored in parallel to the machine connected panel. from out side, by any competent authorized person, while sitting in his office. (Wireless laptop connectivity)
Benefits of Scada :
  • Report Generation in Access / Excel
  • Use of unlimited storage of PC (Particularly) ‘n’ of recipes
  • Connectivity to any type of Printer.
  • Graphical system representation
  • Real time trending
  • Alarm History.
  • Audit trail
  • Advanced security Level

Rotary Tablet Press Specification

TYPE ACT – II 31 ACT II 37 ACT – II 45
TYPE OF TOOLING D (EU-D. IPT D) B (EU-B. IPT B) BB (EU-B. IPT B)
OUTPUT – TABLET / HOUR 22,320 TO 139500 26,640 TO 166,500 32,400 TO 2,02,500
MAX. OPERATION PRESSURE MAIN (KN) 100 100 100
MAX. OPERATION PRE –PRESSURE TAMP (KN) 100 100 100
MAX. TABLET DIAMETER (MM) 25 16 11
MAX. TABLET THICKNESS (MM) 8.5
MAX. DEPTH OF FILL (MM) 3 – 10 FOR “D” & “B” & “BB” Tooling
8.5 – 14 “D” & “B” & “BB” Tooling
12.5 – 20 SUITABLE FOR “D” Tooling
UPPER PUNCH ENTRY MAIN (MM) 1 TO 6
UPPER PUNCH ENTRY PRE- COMPRESSION (MM) 1 TO 6
POWER – TOTAL (KW/HP) 9/12
MAIN ELE. MOTOR (KW/ HP) 7.5/10, 1440 RPM
PRE.PRESS ROLL ELE MOTOR(KW/HP) 0.12/0.16, 1440 RPM
MAIN PRESS ROLL ELE. MOTOR (KW/ HP) 0.12/ 0.16, 1440 RPM
WEIGHT ADJ. ELE MOTOR (KW/HP) 0.025/0.0335, 1440 RPM
FEEDER ELE. MOTOR (KW/HP) 0.37/0.50, 1440 RPM
TURRET LIFTING ELE. MOTOR (KW/HP) 0.75/1, 1440 RPM
OVERALL DIMENSIONS (CM) 124.5 W X 134.5 L X 203.5 H (WITH CLOSE GUARD)
OVERALL DIMENSIONS (CM) 234 W X 281 L X 203.5 H (WITH OPEN GUARD)
NET WEIGHT (KG) 3000.00 KG (APPROX)
CASE DIMENSION (CM) 185 X 185 X 220 H
UTILITIES (1) Suction Air 300 CFM
accura act ii single rotary accura act ii single rotary tablet press accura act ii single rotary tablet press machine single rotary Tablet press machine
single rotary tablet press accura act ii single rotary Tablet press machine manufacturer accura single rotary tablet press accura single rotary tablet press machine